diagtrack.dll

Associated Error Codes

Below lists error codes and symbolic names found for this module.

CodeFound inDescription
0x1100000110System Global Consent
0x1100000710Failure
0x300000001011Info
0x500000021011Error
0x500000031011Warning
0x500000041011Information
0x7100000a10Diagnostic Data Value Changed
0x7200000a10Tailored Experiences Value Changed
0x9100000110Microsoft-Windows-Privacy-Auditing-DiagnosticData
0x9200000110Microsoft-Windows-Privacy-Auditing-TailoredExperiences
0xb00000011011Tenant %2 has been registered for telemetry usage.
0xb00000021011Tenant %2 has been unregistered for telemetry usage.
0xb00000031011The daily upload quota for %2 has been updated to %3 bytes.
0xb00000141011The upload URL has changed to %2 .
0xb00000151011Upload failed with the following HRESULT: %2
0xb00000161011The daily upload quota for SENSE has crossed into a new tier.
0xb00000171011Storage capacity for the SENSE tenant has changed to a new tier.
0xb00000181011An unknown and unconfigured dynamic Vortex region %2 was attempted to be set.
0xb00000191011The event storage for SENSE has been throttled.
0xb000001a1011The upload for SENSE has been throttled.
0xb000001b1011Connection state - All connections have succeeded since the previous period.
0xb000001c1011Connection state - Some connections have failed since the previous period.
0xb000001d1011Connection state - Some connections have failed since the previous period.
0xb000003210The service has been started to the following state: %2 .
0xb00000371011Is the Internet available: %2
0xb00000381011Is a free network available: %2
0xb000003c1011Is device on battery power: %2
0xb000003d1011Is the Battery Saver state enabled: %2
0xb000003e1011Is the device in connected standby: %2
0xb000003f1011Has the service used more power than considered reasonable: %2
0xb00000401011Diagnostic Data Collection Level
0xb00000411011The agent has transitioned to or from an idle state.
0xb00000421011The diagnostic and feedback permission level has changed.
0xb00000441011Invalid Processor mode configuration.
0xb10003e810The Diagnostic Data Value was changed from %4 to %5 by %2
0xb10003e910The Diagnostic Data Value failed to change from %4 to %5 by %2
0xb20003e810The Tailored Experiences Value was changed from %4 to %5 by %2
0xb20003e910The Diagnostic Data Value failed to change from %4 to %5 by %2
0x1100001111PerfTrack Status
0x1100001211SQM Status
0x1100003111Response Time
0x3100000111Start
0x3100000211Stop
0x5100000511Verbose
0x9100000111Microsoft-Windows-Diagnostics-PerfTrack
0xb000003211The service has been started to the following state: %2.
0xb000004311You cannot enable a policy that causes your organization to manage all Windows diagnostic data without being AAD joined or setting a valid CommercialId on the device.
0xd000000111Shutdown
0xd000000211Startup
0xd000000311Running
0xd000000411Updating Scenarios
0xd000000511Stopping
52 entries