ptpprov.dll

Associated Error Codes

Below lists error codes and symbolic names found for this module.

CodeFound inDescription
0x500000031011Warning
0x500000041011Information
0x900000011011Microsoft-Windows-Time-Service-PTP-Provider
0xb00002001011PTP provider started receiving announcements from the PTP Master %1 with IP Address %2 on local IfIndex:%15 and the following PTP parameters: Clock Identity:%3 Port Number:%4 Domain Number:%5 Utc Offset Valid:%6 Current UTC Offset:%7 Flags:%8 Grandmaster Clock Id:%9 Steps Removed From GM:%10 Time Source Code:%11 Announce Interval (Log2):%12 Number of active Masters:%13 Current Tick Count:%14 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb00002011011PTP provider has chosen the PTP Master %1 with IP Address %2 on local IfIndex:%14 as the best master and the source of time. This master is announcing the following PTP parameters: Clock Identity:%3 Port Number:%4 Domain Number:%5 Utc Offset Valid:%6 Current UTC Offset:%7 Flags:%8 Grandmaster Clock Id:%9 Steps Removed From GM:%10 Time Source Code:%11 Announce Interval (Log2):%12 Current Tick Count:%13 If the best master keeps changing frequently, verify that the masters and this client have the same announce interval configured. For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb000020210PTP Master %1 with IP Address %2 has made no announcements in the last announce timeout window (%3 milliseconds). It is excluded from being considered as a (potential) time source. PTP Master parameters: Clock Identity:%4 Port Number:%5 Announce Interval (Log2):%6 Number of active Masters:%7 Current Tick Count:%8 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb000020310Ptp Provider Configuration: Allowed Masters:%1 Allow Any Master:%17 Announce Interval:%2(msec) Delay Poll Interval:%3(msec) Timestamping Allowed:%4 Multicast Rx Enabled:%11 PTP E2E Correction Enabled:%13 HW TSTMP IfIndex:%14 Multicast-Only Tx Enabled:%15 Multicast IfIndex:%16 (IfIndex: 0 = none chosen, (1, ULONG_MAX) = specific interface, ULONG_MAX = all available) PTP provider status: PTP Best Master Details: Name:%5 IP Address:%6 Clock Identity:%7 Port Number:%8 Tick Count At Last Time Sample:%9 ActiveMasterCount:%10 Current Tick Count:%12 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb00002041011Messages from PTP Master will be ignored because the master is not allowed. PTP Master parameters: IP Address:%1 Clock Identity:%2 Port Number:%3 Domain Number:%4 Utc Offset Valid:%5 Current UTC Offset:%6 Flags:%7 Grandmaster Clock Id:%8 Steps Removed From GM:%9 Time Source Code:%10 Announce Interval (Log2):%11 Number of active Masters:%12 Current Tick Count:%13 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb000020510PTP provider is configured to receive hardware timestamps from these network interfaces: InterfaceList:%1 Current Tick Count:%2 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb00002061011PTP provider can translate hardware timestamps from the NIC with IfIndex %1 Current Tick Count:%2 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb00002071011PTP provider is unable to translate hardware timestamps from the NIC with IfIndex %1 Current Tick Count:%2 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb00002081011PTP provider is configured to accept announcements from any master on the network. Ensure that this setting is intentional. This message will repeat periodically. Number of active Masters:%1 Current Tick Count:%2 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb000020910PTP provider is receiving timestamps from the network stack. These typically help reduce the jitter in time error calculations and improve time sync accuracy. Current Tick Count:%1 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb000020a1011PTP provider is not receiving any timestamps from the network stack, which may result in lowered time sync accuracy. This is the default configuration and the behavior on service startup. This can also occur if there are conflicting settings for a NIC or due to actual runtime issues. Current Tick Count:%1 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb000020211PTP Master %1 with IP Address %2 has made no announcements in the last announce timeout window (%3 milliseconds). It is excluded from being considered as a (potential) time source. PTP Master parameters: Clock Identity:%4 Port Number:%5 Domain Number:%9 Announce Interval (Log2):%6 Number of active Masters:%7 Current Tick Count:%8 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb000020311Ptp Provider Configuration: Allowed Masters:%1 Allow Any Master:%17 Local Domain Number:%18 Announce Interval:%2(msec) Delay Poll Interval:%3(msec) Timestamping Allowed:%4 Multicast Rx Enabled:%11 PTP E2E Correction Enabled:%13 HW TSTMP IfIndex:%14 Multicast-Only Tx Enabled:%15 Multicast IfIndex:%16 (IfIndex: 0 = none chosen, (1, ULONG_MAX) = specific interface, ULONG_MAX = all available) PTP provider status: PTP Best Master Details: Name:%5 IP Address:%6 Clock Identity:%7 Port Number:%8 Domain number:%19 Tick Count At Last Time Sample:%9 ActiveMasterCount:%10 Current Tick Count:%12 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb000020511PTP provider has detected the following timestamping capabilities (IF_INDEX values printed): Hardware timestamping available on network interfaces:%1 Software timestamping available on network interfaces:%2 Ambiguous timestamp settings on network interfaces:%3 No timestamping available on network interfaces:%4 Current Tick Count:%2 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb000020911PTP provider is receiving timestamps from the network stack. These typically help reduce the jitter in time error calculations and improve time sync accuracy.Some timestamps need to be translated before use. Look for other events for more information on timestamp translation. Current Tick Count:%1 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
0xb000020b11The timestamp settings on the NICs in this system are ambiguous, with a combination of different kinds of timestamping enabled. The resulting timestamps may not be translated correctly, resulting in sub-optimal time sync accuracy. There could also be path asymmetry due to the use of different kinds of timestamp types on different NICs in the system. For best results, enable a single kind of timestamping on all NICs in the system. Current Tick Count:%1 For more information, see https://go.microsoft.com/fwlink/?linkid=873491.
19 entries